Bidirectional linking between AutoCAD Plant 3D P&ID components and Revit elements
P&ID Link installs as a pair of add-ins: one for Revit and one for AutoCAD Plant 3D. Both must be installed, and both applications should be open at the same time for linking and navigation to work.
P&ID Link connects P&ID components in AutoCAD Plant 3D drawings to elements in a Revit model. Once two objects are linked, the pair is remembered permanently, and you can move between them, keep track of which objects are already linked, and copy P&ID data into Revit parameters.
On the Plant 3D side, P&ID Link works with P&ID components — the objects that carry data in the project database. Pipe and signal lines are excluded where components are listed.
On the Revit side it works with these categories: Mechanical Equipment, Pipe Accessories, Electrical Equipment, Electrical Fixtures, Data Devices, Duct Accessories, Fire Alarm Devices, Lighting Devices, Lighting Fixtures, Mechanical Control Devices, Plumbing Equipment, Plumbing Fixtures, Security Devices, Sprinklers and Telephone Devices.
| Requirement | Details |
|---|---|
| Autodesk Revit | 2024, 2025, 2026 or 2027 |
| AutoCAD Plant 3D | 2024, 2025, 2026 or 2027, with a Plant 3D project open |
| Operating system | Windows 64-bit |
| Language | English |
| Account | An Autodesk account signed in to both applications |
| Internet | Required occasionally for license verification |
The Revit release and the Plant 3D release do not have to match. For example, Revit 2026 and Plant 3D 2024 can be linked, as long as P&ID Link is installed for both.
In Revit a ribbon tab named P&ID Link appears with the Linking, Overview, Mapping and Info panels. In Plant 3D a ribbon tab appears with a single Link panel.
To uninstall, use Windows Settings › Apps. Saved links and mappings are not removed by the uninstaller.
P&ID Link is licensed per Autodesk account. The license is tied to the Autodesk account that acquired the app from the Autodesk App Store, so you should be signed in to that account in Revit and Plant 3D.
When the add-in starts, it contacts the Autodesk licensing service to confirm that your signed-in account is entitled to use P&ID Link. The add-in sends only your Autodesk user identifier and the application identifier of P&ID Link. No drawing data, model data, file names or personal documents are transmitted.
When P&ID Link is blocked, the About / Privacy button remains available, so you can always read the privacy information and find the support address.
| Button | Panel | What it does |
|---|---|---|
| Pick Element | Linking | Remembers the Revit element you select as the current pick. |
| Link | Linking | Joins the current Revit pick to the current Plant 3D pick. |
| Unlink | Linking | Removes the link and clears the mapped Revit parameters. |
| Element List | Overview | Lists model elements, with filters, and shows which are linked. |
| Param Mapping | Mapping | Defines which P&ID attribute fills which Revit parameter. |
| Sync Params | Mapping | Writes the exported P&ID values into Revit parameters. |
| About / Privacy | Info | Version, privacy policy and support information. |
| Button | Command | What it does |
|---|---|---|
| Pick | PRLPICK | Remembers the P&ID component you select as the current pick. |
| Link | PRLLINK | Joins the current Plant 3D pick to the current Revit pick. |
| Unlink | PRLUNLINK | Removes the link between the two current picks. |
| Export Attributes | PRLATTRS | Collects attribute names so Revit can offer them for mapping. |
| Export Values | PRLEXPORTVALUES | Reads values of linked components in the current drawing. |
| Export All | PRLEXPORTALL | Reads values across every drawing referenced by the links. |
| Show Unlinked | PRLSHOWUNLINKED | Selects the components in this drawing that are not linked. |
| About / Privacy | PRLABOUT | Version, privacy policy and support information. |
Every Plant 3D button can also be typed at the command line. Pressing F1 on a button opens this help page.
A link always joins exactly one P&ID component to exactly one Revit element. The order of the first two steps does not matter.
Unlinking is deliberately strict. Both sides must be picked, and the two picked objects must belong to the same link. If only one side is picked, or the two picks are not partners, nothing is removed and a message explains why.
When a pair is removed, any Revit parameters filled through the mapping are cleared, so no stale values are left behind in the model.
If the linked component is in a drawing that is not currently open, Plant 3D opens that drawing and then zooms to it. If the drawing has been moved or renamed, a message reports that it could not be found on disk.
In a workshared Revit model, if the linked element is on a workset that is not currently open, Revit opens that workset in order to show the element. The workset stays open for the rest of the session.
Element List in Revit shows the elements of the supported categories with their level, family, type, category and object ID. Linked rows are marked with a green dot and grouped at the top.
Each column header carries a filter arrow. Click it to choose which values to show, in the same way as a spreadsheet filter. A search box narrows long lists, and filtered columns are shown in blue. Clear Filters resets them all. Filters are remembered while the application stays open.
On the Plant 3D side, Show Unlinked selects every component in the current drawing that is not yet linked, so the remaining work is highlighted directly in the drawing.
If a linked Revit element is deleted, its link is removed automatically so the overview stays accurate. In workshared models this clean-up is deliberately conservative: links are kept rather than removed when an element cannot be found, so nothing is lost while part of the model is not loaded.
P&ID Link supports workshared Revit models. When the model you open is workshared, links and mappings are stored in a shared folder beside the central model, so the whole team sees the same links.
A folder named PIDLink_Data is created next to the central model file. It holds
the links, the parameter mappings and the exported P&ID values. Everyone who uses P&ID
Link on that project needs read and write access to that folder.
If the folder cannot be created — for example because the project folder is read-only — P&ID Link continues to work using local storage on that computer instead, and the links are simply not shared.
For a model that is not workshared, nothing changes: links stay on your own computer.
Although links are shared with everyone on a workshared model, it works best if one person is responsible for creating and removing them. Linking is not merged between users: if two people link the same object to different partners, the later link replaces the earlier one without warning.
Everyone on the team can open the Element List, navigate between linked objects and run Sync Params. It is only the creating and removing of links that is best kept with one person.
| Situation | What to do |
|---|---|
| The ribbon tab is missing in Plant 3D | Restart Plant 3D so the ribbon is rebuilt. If it is still missing, reinstall for that release. |
| A command reports that the license could not be verified | Connect to the internet, make sure you are signed in to the Autodesk account that acquired P&ID Link, and restart the application. |
| Link says no object is remembered | Both sides must be picked before linking. Use Pick in Plant 3D and Pick Element in Revit, then click Link. |
| Unlink says the objects are not linked to each other | Unlinking requires both sides picked and both belonging to the same pair. |
| No Plant 3D project is open | P&ID Link reads the P&ID project database, so a project must be open, not just a drawing. |
| Sync reports that a parameter is read-only or missing | The Revit parameter must exist on the element and be writable. Check that the shared parameter is loaded and bound to the category. |
| Sync finds no values | Run Export Values or Export All in Plant 3D first. |
| A colleague cannot see my links | Links are shared only for workshared Revit models, through the PIDLink_Data folder beside the central model. Check that everyone has access to that folder. |
| Plant 3D cannot find a linked drawing | The drawing was moved or renamed after the link was created. Restore the file, or unlink and link again. |
For a workshared Revit model: <central model folder>\PIDLink_Data
Otherwise, and for your own current selection in either application:
%LOCALAPPDATA%\PIDLink
Nothing is stored inside the drawing or the model, and nothing is sent anywhere.
Questions, problems and feature requests are welcome by email. Please include the Revit and Plant 3D releases you are using and a short description of what you were doing when the problem appeared.
| Contact | |
|---|---|
| info.dev4revit@gmail.com | |
| Privacy policy | privacy-pidlink.html |
| Home | dev4revit.github.io |